marque: Tranchart
transport: Ocean,Land
Lieu d'origine: Chine
Hafen: Shanghai,Ningbo,Nantong
Type de paiement: L/C,T/T
Incoterm: FOB,CFR
Présentation :
PRODUCT NAME: | XGN58 (HXGT6A)-24 Box Type Gas Insulated Metal-clad Switchgear | TYPE: | Box Type |
RATED VOLTAGE: | 24Kv | RATED CURRENT: | 630A |
APPLICATION: | Indoor | RATED FREQUENCY: | 60Hz |
RATED SHORT CIRCUIT BREAKING CURRENT: | 25kA | APPLICABLE STANDARD: | GB3906, IEC62271-200 |
Conditions de service
1. Altitude: pas plus de 3000 m au-dessus du niveau de la mer;
2. Température ambiante: max: + 40 ℃, min: -40 ℃;
3. Humidité relative: la moyenne quotidienne ne dépasse pas 95%, la moyenne mensuelle ne dépasse pas 90%;
4. Aucune pollution apparente du gaz corrosif ou combustible autour, l'intensité sismique n'est pas supérieure à huit classes.
5. Aucune vibration violente régulière, l'intensité sismique ne dépasse pas huit classes;
Remarque: Si l'écart des conditions de service normal se produit, le client peut négocier avec le fabricant.
Caractéristique
* Équipé d'un commutateur de charge, de chargement de composite de fusibles Swith, d'unité de fonction de disjoncteur de circuit, sa fonction est très complète.
* Petit volume, léger, volume minimum pour un seul est de 350 * 820 * 1500 (mm).
* Fonctionnement facile, utilisation sûre, maintenance pratique, l'appareillage de commutation peut être utilisé pendant 30 ans sans maintenance.
* RMU est conçu pour être omniseal, sans partie vivante exposée et peut fonctionner à long terme dans l'environnement défavorable.
Données techniques :
No. | Item | unit | Parameter | |||
1 | Rated voltage | KV | 24 | |||
2 | Rated bus bar current | A | 6,301,250 | |||
3 | Rated current | A | 630 | |||
4 | Rated frequency 1min | HZ | 50/60 | |||
5 | Rated short-time withstand current | KA | 20/4,25/2 | |||
6 | Rated peak withstand current | KA | 50,63 | |||
7 | Rated short-circuit making current | KA | 50,63 | |||
8 | Rated Current of load switchgear with fuse wire | A | 100 | |||
9 | Rated short-circuit breaking current | fuse | KA | 31.5 | ||
Circuit breaker | KA | 20,25 | ||||
10 | 1min Power | (phase to phase/ phase-to-ground/chasm) | KV | 42/48,65/79 | ||
frequency withstand | ||||||
voltage | ||||||
lightning impulse | (phase to phase/ phase-to-ground) (phase to phase/ phase-to-ground | KV | 75/85,125/145 | |||
withstand voltage | ||||||
(peak value) | ||||||
Circuit resistance | Load switchgear | μΩ | 130 | |||
Composite apparatus cabinet(not include fuse resistance) | μΩ | 250 | ||||
Circuit breaker cabinet SF6 | μΩ | 140 | ||||
11 | SF6 Rated Gas pressure | Mpa | 0.04 | |||
(20ºC gauge pressure) | ||||||
12 | SF6 Gas annual Leakage rate | ≤0.2% | ||||
13 | Protection grade (gas filled enclosure) | IP67 |
Groupes de Produits : Anneau d'unité principale RMU > Unité principale de l'anneau isolée en gaz
Mr. simon.tang
Numéro De Téléphone:
86-519-85131880
Fax:
86-519-85131880
E-mail:
site mobile
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.