12kV 630-2000a Vacuum VCB Circuit Breaker STABILITÉ HAUTE
Voltage: | 12-24KV | Current: | 630-2000A |
Breaking Current: | 25KA Max | Type: | Withdrawable |
Standard: | GB,ISO,IEC |
VS1-Series Circuit Breaker présente une stabilité élevée et une forte fiabilité
"Disjonction de circuit à vide à haute tension" est nommé parce que le milieu d'extinction d'arc et le milieu isolant de l'espace de contact après l'extinction de l'arc sont le vide; Avantages, l'application dans le réseau de distribution est plus populaire.
Le disjoncteur est identifié par certaines normes nationales et normes relatives internationales, telles que GB1984, GB / T11022, DL / T403 et IEC62271, etc.
Condition de service
Altitude | ≤1000m | |
Ambient temperature | Max | +40℃ |
Min | -15℃ | |
Ambient humidity: | 24 hours ≤95% | |
Maximum average humidity | 1 month ≤90% | |
Maximum water vapor pressure | 24 hours ≤2.2kpa | |
1 month ≤1.8kpa |
Paramètres techniques
No. | Item | Unit | Parameter | ||||||
1 | Rated voltage | KV | 12 | ||||||
2 | Rated frequency | Hz | 50/60 | ||||||
3 | 1min power frequency withstand voltage(r. m. s) | 42(phase-to-phase, phase-to-earth) | |||||||
Rated insulation level | KV | 48(across the isolating distance) | |||||||
Lighting impulse withstand voltage (peak) | 75(phase-to-phase, phase-to-earth) | ||||||||
85(across the isolating distance) | |||||||||
630 | 630 | 1250 | 1600 | ||||||
1250 | 1250 | 1600 | 2000 | ||||||
4 | Rated current | A | 2000 | 2500 | |||||
2500 | 3150 | ||||||||
4000 | |||||||||
5 | Rated short-circuit breaking current | 20 | 25 | 31.5 | 40 | ||||
6 | Rated short-time withstand current | KA | 20 | 25 | 31.5 | 40 | |||
7 | Rated short-circuit marking current | 50 | 63 | 80 | 100 | ||||
8 | Rated peak withstand current | 50 | 63 | 80 | 100 | ||||
9 | Rated duration of short-circuit | s | 4 | ||||||
10 | Rated operating sequence | O-0.3s-O/C-180s-O/C | |||||||
11 | Breaking times of rated short-circuit current | Times | 30/20 times(40KA) | ||||||
12 | Mechanical endurance | Ops | 20000 | ||||||
13 | Rated single capacitor bank breaking current | 630 | |||||||
14 | Rated back-to-back capacitor bank breaking current | A | 400 | ||||||
15 | Double-earth fault breaking current | 27.4 | |||||||
16 | Allowable maximum contact erosion | 3 | |||||||
17 | Clearance between open contacts | mm | 10±1 | ||||||
18 | Over stroke | 3.5±0.5 | |||||||
19 | Non-simultaneity of 3-phase opening and closing | ms | ≤2 | ||||||
20 | Bounce duration of contact closing | ≤2 | |||||||
21 | Average breaking speed (instant breaking 6mm) | m/s | 1.1±0.2 | ||||||
22 | Average making speed | 0.8±0.2 | |||||||
23 | Making time | ms | ≤100 | ||||||
24 | Breaking time | ≤50 | |||||||
630A | ≤50 | ||||||||
Resistance of each phase main circuit | μ Ω | 1250A | ≤45 | ||||||
25 | 1600A~2000A | ≤35 | |||||||
≥2500A | ≤25 | ||||||||
26 | Contact breaking bounce amplitude | mm | ≤2 | ||||||
Rated operating voltage | Rated operating voltage(V)AC/DC | 24* | 110 | 220 | |||||
27 | Scope of normal operation voltage | V | Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed | ||||||
28 | Rated voltage of energy storage motor | V | AC110/220,DC110/220 | ||||||
29 | Energy storage time | S | ≤15 |
Groupes de Produits : Disjoncteur > Disjoncteur à vide haute tension
Mr. simon.tang
Numéro De Téléphone:
86-519-85131880
Fax:
86-519-85131880
E-mail:
site mobile
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.